In this article we will does discussed about working of single phase transformer and also studied abut connection of single phase and pollyphase system
Working of single phase transformer

In the case of single phase transformers connected to from
three phase bank, each transformer is magnetically decoupled from the other. The
flows of harmonic currents are decided vy the type of the electrical connection
used on the primary and secondary sides. Also, there are three fundamental
voltages in the present case each displaced from the other by electrical degree
of 120. Because of the symmetry of the A.C wave about the time axis only odd
harmonics need to be considered. The harmonics which is triple (multiplies of
three) behave in a similar manner as they are co-phrasal or in phase in the
three phases.
As against a bank of three single phases transformer connected
to three phase mains, In 3-phase shell type transformer generally has the three
magnetic circuits that are interacting from each other. The exception to this rule is a 3-phase shell type transformer. In the shell type of construction,
even though the three cores are together, they are non-interacting each other. Three
limb core type 3-phase transformer is the one in which each phase is
magnetically linked with each other. Flux of each limb uses the other two limbs
for its return path. This is true for fundamental and non-triple harmonics. The
triple harmonics being co-phrasal that cannot use other limbs for the return
path (this holds good for zero sequence, unbalanced fundamental magneto motive
force also). The flux path is completed through the air so substantially large
value of MMF (magneto motive force) produces a low value of harmonic flux in
the core remains nearly sinusoidal.
This happens irrespective of the type connection used. The triple
order flux sometimes links the tank and produces loss in the same.
In place of this, a three-phase transformer wound on common
core offers number of advantage over a bank of single-phase transformers. A
three-phase transformer wound on a common core is lighter, smaller and cheaper
than the bank of three-phase transformers. It means it is better than bank of transformer.
The common core three-phase transformer also requires much less external wiring
than the bank of single phase transformer also requires much less higher efficiency.
The bank of three single-phase transformers does offer the advantage of flexibility.
In the case of an unbalanced load, one or more transformer in the bank can be
replaced by a larger or smaller KVA-rated transformer. In terms of maintenance,
a malfunctioning transformer in the bank of transformers can be easily replaced
while the entire common core three phase transformers would require replacement.
so it is working of single phase transformer.
Poly phase connection of transformer
Because of various advantages of polyphase power during generation,
transmission and utilization, polyphase handling and operations are very important. From the
poin techno-economic considerations, no single connection or setup is
satisfactory for all applications and of various forms. Star and mesh
connections are very commonly used forms. Apart from these,vee or open delta
connections, zig-zig connections, T connections auto transformer connections,
multi winding transformer etc.